# 12 V voltage drop calculator > How much voltage do you lose in a 12 V cable? A 12 V DC circuit with a 3 % limit: find the wire size that keeps the drop small over your cable length. Calculate the voltage drop of a 12 V DC cable for a van, boat, caravan or solar setup, and the smallest wire size that keeps it within 3 per cent. A preset of [Voltage drop calculator](https://how.box/voltage-drop/). - Page: https://how.box/12v-voltage-drop/ - Runs entirely in the browser. - License: HowToolbox's own text and data (titles, explanations, FAQs, tool descriptions and schemas, this file) are CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/); AI training and answers are welcome. Attribute "HowToolbox (how.box)" with a link to the page used. Third-party data keeps its own terms; the name and logo are not licensed. Publisher: HowToolbox, contact@how.box. Terms: https://how.box/about/terms/ ## Inputs Answer link: https://how.box/12v-voltage-drop/?s={s}&v={v}&i={i}&l={l}&lu={lu}&a={a}&au={au}&c={c}&max={max} - `s` (dc, single-phase or three-phase): dc, single-phase or three-phase. Example: `single-phase`. - `v` (number 0.1 to 100000): Supply voltage, volts. Example: `230`. - `i` (number 0.001 to 10000): Load current, amperes. Example: `16`. - `l` (number 0.01 to 1e6): One-way length in lu. Example: `30`. - `lu` (m or ft): m or ft. Example: `m`. - `a` (number -3 to 10000): Conductor size in au (mm² or AWG gauge). Example: `2.5`. - `au` (mm2 or awg): mm2 or awg. Example: `mm2`. - `c` (annealed-copper or aluminium): annealed-copper or aluminium. Example: `annealed-copper`. - `max` (number 0.1 to 50): Largest allowed drop, per cent. Example: `3`. Example answer: https://how.box/12v-voltage-drop/?s=single-phase&v=230&i=16&l=30&lu=m&a=2.5&au=mm2&c=annealed-copper&max=3 A complete link carries the primary answer in the page HTML; a missing or invalid value shows the default page. ## Agent tools - `voltage_drop_calculate`: Voltage drop of a cable run (resistive, 20 °C, no reactance; not an installation rule): two wires out and back for dc and single-phase (2·I·R), √3·I·R line-to-line for balanced three-phase. - MCP, one POST to https://how.box/mcp: `{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"voltage_drop_calculate","arguments":{"supply":"single-phase","voltage":230,"current":16,"length":30,"length_unit":"m","size":2.5,"size_unit":"mm2","conductor":"annealed-copper","max_percent":3}}}` - GET: https://how.box/mcp/run/voltage_drop_calculate?supply=single-phase&voltage=230¤t=16&length=30&length_unit=m&size=2.5&size_unit=mm2&conductor=annealed-copper&max_percent=3 ## How it works On a 12 V circuit a few tenths of a volt are a large share of the supply. The wire carries the current out and back, so the drop is 2 × I × R, with R = ρ × L ÷ A for one conductor (copper ρ = 1/58 Ω·mm²/m). The same drop in volts is a much larger share of 12 V than of 230 V. The table below gives the smallest copper wire for a 3 per cent drop, which is 0.36 V on 12 V, by current and one-way length. The AWG gauge is the thinnest standard gauge that is thick enough. Doubling the length or the current doubles the wire you need. This is a resistive estimate at 20 °C. Warm cables have more resistance, so real drops are a little higher. It does not size a cable for heating or protection: the current a cable may carry and the fuse come from your wiring regulations. ## FAQ **Why does a 12 V circuit need such thick wire?** The same power takes ten times the current at 12 V compared with 120 V, and the volts lost in the wire grow with the current. Losing 0.36 V is already 3 % of 12 V, while on a 230 V circuit it would be a tiny fraction. For example, 10 A over 5 m of 2.5 mm² copper loses about 0.7 V, nearly 6 %. **Where does the 3 % limit come from?** Boat wiring guidance commonly allows 3 % for critical circuits such as navigation lights, electronics and pumps, and 10 % for less critical ones like cabin lighting. The calculator uses 3 %; open the extra options and set the largest drop to 10 to see the looser case. **Is the length one way or the round trip?** Enter the one-way length from the supply to the load. The calculator counts the current going out and coming back along two wires, so you do not double it yourself. **Does this also work for 24 V or 48 V?** Yes. Change the voltage and keep the supply on DC. For the same current the volts lost stay the same, but they are a smaller share of a higher voltage, so a 24 V circuit can use thinner wire for the same percentage. **Does a longer cable need a thicker wire?** Yes, in proportion: for the same drop, twice the length needs twice the cross-section. The table shows the sizes for 2, 5 and 10 m. More: [HowToolbox index](https://how.box/llms.txt) · [Agent Skill](https://how.box/skill.md) · [agent terms](https://how.box/about/agents/)