# AC power calculator > How much of the power does real work? The power triangle of an AC load: watts, vars and volt-amperes, the power factor and the capacitor that corrects it. Drag the triangle's tip. Calculate real, reactive and apparent power from voltage, current and power factor, single or three-phase, with the phase angle and power-factor correction. - Page: https://how.box/ac-power/ - Runs entirely in the browser. - License: HowToolbox's own text and data (titles, explanations, FAQs, tool descriptions and schemas, this file) are CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/); AI training and answers are welcome. Attribute "HowToolbox (how.box)" with a link to the page used. Third-party data keeps its own terms; the name and logo are not licensed. Publisher: HowToolbox, contact@how.box. Terms: https://how.box/about/terms/ ## Inputs Answer link: https://how.box/ac-power/?ph={ph}&v={v}&i={i}&pf={pf}&load={load}&to={to} - `ph` (single or three): single or three. Example: `three`. - `v` (number 0 to 1e6): RMS voltage, V (line-to-line for three-phase). Example: `230`. - `i` (number 0 to 1e6): RMS line current, A. Example: `10`. - `pf` (number 0 to 1): Power factor, 0 to 1. Example: `0.8`. - `load` (lagging or leading): lagging (inductive) or leading (capacitive). Example: `lagging`. - `to` (number 0 to 1): Target power factor for correction. Example: `0.95`. Example answer: https://how.box/ac-power/?ph=three&v=230&i=10&pf=0.8&load=lagging&to=0.95 A complete link carries the primary answer in the page HTML; a missing or invalid value shows the default page. ## Agent tools - `ac_power_calculate`: AC power of a load: real power (W), reactive power (var), apparent power (VA), power factor and phase angle, and the capacitor needed to correct the power factor. - MCP, one POST to https://how.box/mcp: `{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"ac_power_calculate","arguments":{"phases":"three","voltage":230,"current":10,"power_factor":0.8,"load":"lagging","target_pf":0.95}}}` - GET: https://how.box/mcp/run/ac_power_calculate?phases=three&voltage=230¤t=10&power_factor=0.8&load=lagging&target_pf=0.95 ## How it works In an AC circuit the current does not always rise and fall in step with the voltage. Motors and other coils make it lag behind, capacitors make it lead. Out of step, part of the energy only sloshes back and forth between the supply and the load every cycle, doing no work but still loading the wires. The power factor says how much of the current is useful. The apparent power is S = V × I in volt-amperes (√3 × V × I for three-phase, with V between two lines). The real power is P = S × cos φ in watts, and the reactive power Q = S × sin φ in volt-amperes reactive (var), where φ is the phase angle between voltage and current and cos φ the power factor. They form a right triangle, S² = P² + Q². A motor drawing 10 A at 230 V with a power factor of 0.8 takes 2.3 kVA but uses 1.84 kW; Q = 2.3 × 0.6 = 1.38 kvar. A capacitor in parallel supplies the reactive power locally, so the line current falls: to go from cos φ₁ to cos φ₂ it needs Q = P × (tan φ₁ − tan φ₂). The calculation assumes sinusoidal voltages and currents (no harmonics) and, for three-phase, a balanced load. Based on OpenStax University Physics, volume 2, section 15.4 (openstax.org) and Wikipedia's article on power factor. ## FAQ **Why does a low power factor matter if I only pay for kWh?** Homes usually pay only for real energy, but the wires, fuses and transformers must carry the full current. Businesses are often charged for reactive power or a low power factor for that reason. **What is the difference between kW and kVA?** kW is the real power that does work or makes heat; kVA is voltage times current. Generators, UPS units and transformers are rated in kVA because the current heats them whatever the power factor. **Can the power factor be above 1?** No. The real power can never exceed voltage times current, so cos φ is at most 1, reached by a purely resistive load such as a kettle or heater. **What does three-phase change?** For a balanced load the apparent power is √3 × V × I with V the voltage between two lines (400 V in much of Europe). The power factor and the triangle work the same way. **How do I correct a poor power factor?** Connect capacitors in parallel with the load: they supply the reactive power that the motor would otherwise draw from the grid. The tool shows the kvar to fit and the current you save. More: [HowToolbox index](https://how.box/llms.txt) · [Agent Skill](https://how.box/skill.md) · [agent terms](https://how.box/about/agents/)