# Voltage drop calculator > How much voltage does your cable lose? The voltage lost along a cable run, the voltage left at the load and the smallest wire within your limit. Calculate the voltage drop of a DC, single-phase or three-phase cable in mm² or AWG, the voltage at the load, heat lost and the smallest wire for a limit. - Page: https://how.box/voltage-drop/ - Runs entirely in the browser. - License: HowToolbox's own text and data (titles, explanations, FAQs, tool descriptions and schemas, this file) are CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/); AI training and answers are welcome. Attribute "HowToolbox (how.box)" with a link to the page used. Third-party data keeps its own terms; the name and logo are not licensed. Publisher: HowToolbox, contact@how.box. Terms: https://how.box/about/terms/ ## Inputs Answer link: https://how.box/voltage-drop/?s={s}&v={v}&i={i}&l={l}&lu={lu}&a={a}&au={au}&c={c}&max={max} - `s` (dc, single-phase or three-phase): dc, single-phase or three-phase. Example: `single-phase`. - `v` (number 0.1 to 100000): Supply voltage, volts. Example: `230`. - `i` (number 0.001 to 10000): Load current, amperes. Example: `16`. - `l` (number 0.01 to 1e6): One-way length in lu. Example: `30`. - `lu` (m or ft): m or ft. Example: `m`. - `a` (number -3 to 10000): Conductor size in au (mm² or AWG gauge). Example: `2.5`. - `au` (mm2 or awg): mm2 or awg. Example: `mm2`. - `c` (annealed-copper or aluminium): annealed-copper or aluminium. Example: `annealed-copper`. - `max` (number 0.1 to 50): Largest allowed drop, per cent. Example: `3`. Example answer: https://how.box/voltage-drop/?s=single-phase&v=230&i=16&l=30&lu=m&a=2.5&au=mm2&c=annealed-copper&max=3 A complete link carries the primary answer in the page HTML; a missing or invalid value shows the default page. ## Agent tools - `voltage_drop_calculate`: Voltage drop of a cable run (resistive, 20 °C, no reactance; not an installation rule): two wires out and back for dc and single-phase (2·I·R), √3·I·R line-to-line for balanced three-phase. - MCP, one POST to https://how.box/mcp: `{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"voltage_drop_calculate","arguments":{"supply":"single-phase","voltage":230,"current":16,"length":30,"length_unit":"m","size":2.5,"size_unit":"mm2","conductor":"annealed-copper","max_percent":3}}}` - GET: https://how.box/mcp/run/voltage_drop_calculate?supply=single-phase&voltage=230¤t=16&length=30&length_unit=m&size=2.5&size_unit=mm2&conductor=annealed-copper&max_percent=3 ## How it works Every cable has a little resistance, and current through a resistance costs voltage. A long or thin cable, or a large current, leaves noticeably less voltage at the load than at the supply, and the lost part turns into heat in the cable. Motors then start harder, lamps dim and electronics may reset. For DC and single-phase, the current goes out along one conductor and back along the other, so the drop is ΔV = 2 × I × R, where I is the current and R = ρ × L ÷ A the resistance of one conductor of length L and cross-section A (copper: ρ = 1/58 Ω·mm²/m). For a balanced three-phase load the drop between lines is ΔV = √3 × I × R. A 16 A load at the end of 30 m of 2.5 mm² copper loses 2 × 16 × 30 ÷ 58 ÷ 2.5 = 6.6 V, 2.9 % of 230 V. This is a resistive estimate at 20 °C. Warm cables have a few per cent more resistance and large AC cables add reactance, so real drops are somewhat higher. It is not a cable sizing rule: the current a cable may carry, protection and the allowed drop come from your local wiring regulations. Sources: OpenStax University Physics, volume 2, section 9.3, and the conventions of IEC 60364-5-52. ## FAQ **Does a larger AWG number mean a thicker conductor?** No. A larger AWG number means a thinner conductor. Switch the size unit to AWG before entering the gauge. **Which voltage should I enter for a three-phase supply?** Enter the line-to-line voltage and the current in each line. The three-phase calculation assumes the load is balanced. **How do I reduce voltage drop?** Use a thicker cable, a shorter run or a higher supply voltage: the same power at a higher voltage needs less current. Doubling the cross-section halves the drop. **Why does a 12 V system need such thick cables?** The same power at 12 V takes about 19 times the current of 230 V, and a fixed number of volts lost is a far bigger share of 12 V. Short runs and thick cables keep the loss down. **Is the mm² input the cable diameter?** No. It is the cross-sectional area of one conductor, excluding insulation. A diameter in millimetres cannot be entered as though it were an area in square millimetres. More: [HowToolbox index](https://how.box/llms.txt) · [Agent Skill](https://how.box/skill.md) · [agent terms](https://how.box/about/agents/)