How many lux is a foot-candle reading?
Multiply foot-candles by 10.764 to get lux, or enter any reading.
What you enter stays on your device while you use this tool. Opening a shared link sends the settings in its address to HowToolbox to prepare the page.
Result
107.6 lx
10 foot-candles is about 107.6 lux
- The other way round: 1 lx = 0.09290304 fc.
In all units
- Lux
- 107.6 lx
- Foot-candles
- 10 fc
- Phots
- 0.01076 ph
Multiply foot-candles by 10.764 to get lux, or enter any reading.
How to use
- Type the level in foot-candles, as a US lighting table or specification states it.
- Read the lux below, the unit most light meters and European documents use.
Foot-candles in lux
| Foot-candles | Lux |
|---|---|
| 1 fc | 10.76 lx |
| 3 fc | 32.29 lx |
| 5 fc | 53.82 lx |
| 10 fc | 107.6 lx |
| 30 fc | 322.9 lx |
| 50 fc | 538.2 lx |
| 100 fc | 1,076 lx |
3, 5, 10 and 30 fc are the minimums in OSHA 29 CFR 1926.56, Table D-3.
How it works
A foot-candle is one lumen per square foot, so converting to lux means counting how many square feet fit in a square metre: 1 fc = 1 ÷ 0.3048² = 10.7639 lux. The factor is exact, because the foot is defined as 0.3048 metres.
US safety rules state light levels in foot-candles. OSHA's table of minimum illumination for construction sites lists 3 foot-candles for general areas and access ways, 5 for indoor corridors and warehouses, 10 for shops and workrooms, and 30 for first-aid stations and offices. The table below includes those values. To check a measured reading against a requirement, convert once and compare in the same unit: 5 fc is 53.8 lux.
Rounding 1 fc to 10 lux understates the level by about 7 per cent. This converts illuminance only: the lumens of a lamp do not give the foot-candles on a surface without the area they fall on.
Worked example
How many lux is the 30 fc OSHA lists as the minimum for first-aid stations and offices?
- One foot-candle is 10.7639 lux.
- 30 fc × 10.7639 = 322.9 lx
30 fc is 322.9 lx.
Frequently asked questions
How many lux is 50 foot-candles?
About 538 lux.
Is 1 foot-candle about 10 lux?
Close, but a little low: it is 10.76 lux, so rounding to 10 understates the level by about 7 %.
What light level does OSHA require indoors?
For construction work, 5 foot-candles in indoor corridors and warehouses and 30 in offices and first-aid stations, among others. See OSHA 29 CFR 1926.56.
Why do US documents use foot-candles?
They are the unit in US customary lighting practice, where area is counted in square feet. Elsewhere lux is used.





